TL6N

FEATURES
• Aluminium-alloy IP65 single point load cell.
• Colourless anodized
• Suitable for single or double load cell structured platform scales
• Maximum platform size: 400 x 400 mm

SKU: LOAD CELLS 032 Category:
AVAILABLE MODELS
3kg – 100kg Cx (C3 / C4 / C5) L6N-Cx-xxkg-3B6/3YB6
SPECIFICATION DATA
Accuracy class Unit C3 C4 C5
Maximum capacity (Emax) kg 3 / 5 / 8 / 10 / 15 / 20 / 30 / 40 / 50 / 75 / 100
Output sensitivity (=FS) mV/V 2.0 ± 0.2
Combined error %FS ± 0.02 ± 0.015 ± 0.01
Creep (30 minutes) %FS/30min ± 0.0167 ± 0.0125 ± 0.01
Temperature effect on sensitivity %FS/10℃ ± 0.0175 ± 0.0131 ± 0.01
Temperature effect on zero %FS/10℃ ± 0.02 ± 0.012 ± 0.009
Zero balance %FS ± 2
Compensated temperature -10 ~ 40
Operating temperature -35 ~ +65
Input resistance Ω 406 ± 6
Output resistance Ω 350 ± 3
Insulation resistance ≥ 5000 (50VDC)
Excitation, recommended voltage V 5 ~ 12 (DC)
Excitation maximum V 18 (DC)
Safe overload %FS 120
Ultimate overload %FS 150
Protection Class IP65
Cable SPECIFICATIONS mm Φ 4.8
Cable Length m 3
Recommended installation size mm 400 × 400
Corner correction 0.02% load value/100mm
Recommended torque on fixation N.m 10

* Swipe left to view full accuracy specifications →