TH3

FEATURES
• Nickel plated alloy steel IP67 “S”
type load cell
• Tension and compression applications
• Suitable for hanging, hopper and
other weighing devices
• Also available in imperial capacities
and dimensions

SKU: LOAD CELLS 018 Category:

AVAILABLE MODELS

Capacity Accuracy Full article description
25kg C3 (Excluded from OIML) H3-C3-25kg-3B
50kg C3 (Excluded from OIML) H3-C3-50kg-3B
100kg – 750kg C3 / C4 H3-C3/C4-xxkg-3B
1t – 2.5t C3 / C4 H3-C3/C4-xxt-3B
3t – 30t C3 (Excluded from OIML) H3-C3-xxt-3B
* Note: Only 100kg to 2.5t range has OIML certification.
SPECIFICATION DATA
Parameter Unit OIML R60 C3 OIML R60 C4 C3 (Imperial)
Output sensitivity (=FS) mV/V 2.0 ± 0.004 (Metric) 3.0 ± 0.008
Maximum capacity (Emax) t 0.025 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.5 / 0.6 / 0.75 / 1 / 1.5 / 2 / 2.5 / 3 / 5 / 7.5 / 10 / 15 / 20 / 30
lb 100 / 150 / 200 / 250 / 300 / 500 / 750 / 1K / 1.5K / 2K / 2.5K / 3K / 5K / 10K / 15K / 20K
Maximum number of load cell intervals (nLC) 3000 4000 3000
Ratio of minimum LC verification interval Y 10000 20000 10000
Combined error %FS ± 0.020 ± 0.018 ± 0.020
Minimum dead load kg 0
Safe overload %FS 150
Ultimate overload %FS 300
Zero balance %FS ± 1.5 (Metric) ± 1.0 (Imperial)
Excitation, recommended voltage V 5 ~ 12 (DC)
Excitation maximum V 18 (DC)
Input resistance Ω 350 ± 3.5
Output resistance Ω 351 ± 2.0
Insulation resistance ≥ 5000 (50VDC)
Compensated temperature -10 ~ +40
Operating temperature -35 ~ +65
Element material Nickel plated alloy steel
Ingress protection (EN 60529) IP67
Recommended torque on fixation N.m M8: 25
M10: 50
M12: 75
M20: 450
M33: 750
ATEX classification (optional)
II1G Ex ia IIC T4 II1D Ex iaD 20 T73℃ II3G Ex nL II C T4

* Swipe left to view all data →